Design Controller Using the Design Tool
3-25
In the Output weights section, change the reactant concentration's Weight (last
entry in the second row) from the default 1.0 to 0.
Controller Options — Weight Tuning Tab
Test the changes using the T Setpoint scenario (click the toolbar's Simulation button).
Improved Setpoint Tracking for CSTR Temperature shows that the CSTR temperature
now tracks the setpoint change smoothly, reaching the new value in about 10 time units
with no overshoot.