Identifying Low-Order Transfer Functions (Process M odels)
status eld species whether to estimate the parameter, or keep the initial
value xed (do not estimate), or set the value to zero. This eld can have
the values
'estimate', 'fixed',or'zero'. F or more information, see
“Options for Initial States” on page 3 -3 9.
min species the minimum bound on the parameter.
max species the maximum bound on the parameter.
value species the numerical value of the parameter, if known.
To set the value of
K to 12 and keep it xed, use the following commands:
mod.K.value=12;
mod.K.status='fixed';
Note mod is dened for one input. This model is automatically adjusted
to have a duplicate for each input.
To estimate Tp1 an d Td only, use the following command:
mod_proc=pem(ze,mod)