MATLAB REAL-TIME WORKSHOP 7 - TARGET LANGUAGE COMPILER Guida Utente Pagina 171

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 386
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 170
Model Execution
6-9
continuous blocks, then the integration step size determines the base sample
rate.
For example, if the model code is a controller operating at 100 Hz, then every
0.01 seconds the background task is interrupted. During this interrupt, the
controller reads its inputs from the analog-to-digital converter (ADC),
calculates its outputs, writes these outputs to the digital-to-analog converter
(DAC), and updates its states. Program control then returns to the background
task. All of these steps must occur before the next interrupt.
Vedere la pagina 170
1 2 ... 166 167 168 169 170 171 172 173 174 175 176 ... 385 386

Commenti su questo manuale

Nessun commento