MATLAB CONTROL SYSTEM TOOLBOX 9 Guida Utente Pagina 492

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 649
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 491
inv
11-102
You can verify that
H * Hi
is the identity transfer f uncti on (static gain I).
Limitations Do not use inv to model feedback connections such as
While it seems reasonable to evaluate the corresponding closed-loop transfer
function as
inv(1+g*h) * g
this typically leads to nonminimal closed-loop models. For example,
g = zpk([],1,1)
h = tf([2 1],[1 0])
cloop = inv(1+g*h) * g
yields a third-order closed-loop model with an unstable pole-zero cancellation
at
s = 1.
cloop
Zero/pole/gain:
s (s–1)
-------------------
(s–1) (s^2 + s + 1)
+
G
H
IGH+()
1
G
Vedere la pagina 491
1 2 ... 487 488 489 490 491 492 493 494 495 496 497 ... 648 649

Commenti su questo manuale

Nessun commento