MATLAB CONTROL SYSTEM TOOLBOX 9 Guida Utente Pagina 295

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 649
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 294
Controller Design Using the Root Locus Design GUI
8-35
The step response looks good. However, to be certain that you’ve met your
design specifications, you can check the settling time and peak response
characteristics from the right-click menu. To do this:
1 Right-click anywhere in the plot region.
2 Select Settling Time from the Characteristics menu.
3 Set your mouse pointer to t he settling time marker and click to display the
value.
The LTI Viewer will look like this.
As you can see, the settling t ime is less than .05 seconds, and the overshoot is
less than 5 percent. You’ve met t he design specifications and you’re done. You
didn’t need your closed-loop poles to be entirely in the design region, because
you actually have a sixth-order system with some fast dynamics, as opposed to
having only a second-order system.
Marker for the
settling time
Vedere la pagina 294
1 2 ... 290 291 292 293 294 295 296 297 298 299 300 ... 648 649

Commenti su questo manuale

Nessun commento