Vedere la pagina 142
Validate Requirements Links in a Model
5-7
Fix Invalid Requirements Links Detected by the Model Advisor
In “Check Requirements Links with the Model Advisor” on page 5-4,
three requirements consistency checks generate warnings in the
slvnvdemo_fuelsys_officereq model.
Resolve Warning: Identify requirement links that specify invalid locations within documents
To fix the warning about attempting to link to an invalid location in a requirements
document:
1
In the Model Advisor, select Identify requirement links that specify invalid
locations within documents to display the description of the warning.
This check identifies a link that specifies a location that does
not exist in the Microsoft Word requirements document,
slvnvdemo_FuelSys_DesignDescription.docx. The link originates in the
Terminator1 block. In this example, the target location in the requirements
document was deleted after the requirement was created.
2
Get more information about this link:
a
To navigate to the Terminator1 block, under Block, click the hyperlink.
b
To open the “Requirements Traceability Link Editor” for this link, under
Requirements, click the hyperlink.
3
To fix the problem from the Requirements Traceability Link Editor, do one of the
following: